©2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners.
Integration Note
Manufacturer: RCS
Model Number(s): TR/TS40, TR/TS16, TR/TS60 Thermostat
Minimum Core Module Version:
4.0, build 1583
Document Revision Date: 2/18/2013
OVERVIEW AND SUPPORTED FEATURES
The RCS TR16 and TR40 are retrofit-able RS-485 communicating thermostats that use a 2-piece installation
method to leverage existing HVAC wiring for easy install. Each thermostat consists of two parts: a wall display
unit, which resembles a typical thermostat; and a HVAC Control unit. The WDU is installed using existing
HVAC wires at the desired location, and connected to the HVAC Unit back box via the existing 4-wire run. All
new wire connections can then be made the HVAC unit without running new wires to each thermostat location.
The TS16 and TS40 are variants of the TR16/TR40 that can be used with an HVAC Zone Controller that adds
independent zone control via the use of associated dampers for improved efficiency and distribution. See RCS
for full details.
Independent TR16/TR40 installs, and installs using the TS16/TS40 with ZCV series zone controllers are
compatible with external RS-485 or RS-232 control from g!, and provide reliable two-way control and feedback.
Note: The TR/TS60 is the replacement for the TR/TS40. All steps and notations in this document referencing
the TR/TS40 apply to the TR/TS60. Setup the TR/TS60 exactly as you would a TR/TS40.
RCS THERMOSTATS SUPPORT THE FOLLOWING FEATURES:
Temperature Control: Temperature control can be managed by schedules tied to house modes or by manual
control based on time (Timed Temporary Hold, Temporary Hold and Permanent Hold).
Mode Control: The climate system can be set to run in the following heating and cooling modes: Heat only,
Cool only, Auto Heat Cool (TR40 only) or Off. In addition, systems that have a fan can be set to run in
Automatic mode or Continuous mode.
History View: The history view shows the inside temperature, outside temperature, unit run and fan run times,
and cooling and heating setpoints.
Schedule Control: Multiple schedules may be set up, and are automatically tied to the house mode.
Zone Control: Multi-zone “Smart Damper/Vent” systems using the RCS ZCV series of zone controllers are
compatible with g!.
Remote Sensors: An Outside Temperature Sensor or sensors that replace the room sensor can be read from
RCS climate systems.
Vue de la page 0
1 2 3 4 5 6 ... 10 11

Résumé du contenu

Page 1 - Integration Note

ELAN Home Systems ● 1690 Corporate Circle ● Petaluma, CA 94954 USA tech support: 800.622.3526 • main: 760.710.0990 • sales: 877.289.3526 • email: elan

Page 2 - INSTALLATION OVERVIEW

10 of 11 g! CONFIGURATION DETAILS The following table provides settings used in the g! Configurator when connecting to an RCS thermostat network. Ple

Page 3

11 of 11 COMMON MISTAKES 1. Programming two thermostats with the same address. 2. Incorrect serial type setting. The RCS Thermostat Network Communic

Page 4 - ILL OF MATERIALS

2 of 11 RCS THERMOSTATS DO NOT SUPPORT THE FOLLOWING FEATURES: Any feature not specifically noted as “supported” is not supported. Mode Control: Auto

Page 5

3 of 11 ZONED SYSTEM USING A ZCV-SERIES ZONE CONTROLLER 1. Run Cat5 or 18/4 cable from the Wall Display Unit location to the Zone Control Unit locati

Page 6 - (ClipDown)

4 of 11 CONNECTION DIAGRAMS – CONVENTIONAL SYSTEM OVERVIEW BILL OF MATERIALS # Device M anufacturer Part Number Protocol Connector Type Notes1 Wal

Page 7

5 of 11 WIRING DIAGRAM 1: DETAIL OF 485PB WIRING Note: Per RCS Documentation, the 485PB unit is intended for 1 or 2 thermostats with short wiring runs

Page 8 - 8 of 11

6 of 11 WIRING DIAGRAM 2A: DETAIL OF 8AH485D WIRING WIRING DIAGRAM 2B: DETAIL OF 8AH485D COMMUNICATION WIRING V+GD+D‐Cat5CableGreenWhite/OrangeRJ

Page 9 - THERMOSTAT PROGRAMMING

7 of 11 CONNECTION DIAGRAMS – ZONED SYSTEM OVERVIEW BILL OF MATERIALS # Device M anufacturer Part Number Protocol Connector Type Notes1 Wall Displa

Page 10 - CONFIGURATION DETAILS

8 of 11 WIRING DIAGRAM 3: DETAIL OF ZONED HVAC CONTROL SYSTEM

Page 11 - COMMON MISTAKES

9 of 11 THERMOSTAT PROGRAMMING Once the thermostats are powered up and running properly, you need to make a few changes to the thermostat settings to

Commentaires sur ces manuels

Pas de commentaire